Concept

Instrumental-variable — where it appears

A variable that causes the treatment and reaches the outcome only through it. Including one in an adjustment set adds no bias and removes variance from the treatment, which is why it makes an estimate noisier rather than wrong.

Named by 7 essays across 2 fields — each of them below, with the objects they name alongside it.

The first stage an instrument needs is set by the violation nobody can see. The error each estimator converges on when the instrument has a direct effect of 0.05 on the outcome — a path the exclusion restriction asserts is zero and no sample can check. The instrument's error is δ/π exactly, so it is the reciprocal of the very quantity that made the method work: 1.0000 at a first stage of 0.05 and 0.0833 at 0.60. Least squares carries the confounding instead, at 0.3440 at a first stage of 0.30. The two cross at π = 0.1389, and the crossing is exactly δ times 2.7778 — the first stage an instrument needs is proportional to the violation it is assumed not to have, and below that line the method being corrected is the better estimator.

The assumption nothing tests

An instrument buys a causal effect with an assumption no sample can check, and the price is set by the same quantity that made the method work. The first stage it needs is 2.7778 times the violation it is assumed not to have, so a direct effect of 0.05 demands a first stage of 0.1389 and least squares wins below it.

instrument · Exclusion
A weak instrument gives back the problem it was hired for. The counted mean bias of two-stage least squares at 4 instruments and 200 rows, over 2000 draws a setting, against the standard approximation and against the least-squares inconsistency the instrument was brought in to remove. At π = 0.02 the counted bias is 0.3220 ± 0.0142 where least squares is out by 0.3594 — 89.6% of the way back. At π = 0.3 it is 0.0118 against 0.2647. The approximation, the inconsistency over the population first-stage F, tracks the count at the weak end and sits above it in the middle: 0.968, 0.971, 0.918, 0.810, 0.740, 0.722, 0.846 as the ratio of counted to approximated bias.

Weak, and back where it started

A consistent instrumental estimate at two hundred rows and a concentration parameter of 0.32 is biased by 0.3220 ± 0.0142 against a least-squares inconsistency of 0.3594 — 89.6% of the way back to the problem it was hired to solve. Just identified, it has no mean at all, and that is measured as a rate rather than assumed.

instrument · Exclusion
Two structures in three are made worse. What adjusting for every covariate measured does to the bias in the treatment's estimated effect, against adjusting for none, over 4000 randomly drawn structures of 6 covariates each. Each covariate is independently a common cause with probability 0.25, a cause of the treatment only, a cause of the outcome only, a cause of neither, a step on the causal path, or a common effect. The rule leaves a larger bias on 65.5% of structures, a smaller one on 33.8%, and the same on 0.7%. The share is a property of that population of structures rather than of adjustment, which is why the weights are stated; what does not depend on them is that the rule has no direction — it is not a conservative default that occasionally overcorrects, it is a rule whose error is whatever the structure happens to be.

Adjusting for everything

"Control for every covariate that was measured" leaves a larger bias than controlling for nothing on 65.5% of four thousand randomly drawn structures and a smaller one on 33.8%. Its squared error is 4.110 times that of using no covariate at all, and half of it sits in its worst tenth of structures.

collider · Conditioning
Four numbers, and only one of them is the question. Four quantities in a population where the effect is not the same for everybody: 40.0% compliers, 25.0% always-takers and 35.0% never-takers, with the compliers carrying an effect 1.0000 larger than everybody else's. The population average effect is 0.5000. The compliers' average effect is 1.1000. A valid instrument converges on 1.1000 — the second of those, not the first, and the two differ by 0.6000. Comparing the treated with the untreated as they stand gives 1.4182, wrong by 0.9182 in the same direction, because always-takers start 1.5000 above never-takers before any treatment happens. The instrument removes the selection and changes the question at the same time, and only one of those is reported.

Whose effect it is

With a perfectly valid instrument and no violation of anything, the estimate converges on 1.1000 where the population average effect is 0.5000. The gap is exactly θ(1 − p_c), the always-takers and never-takers cancel out of both halves of the ratio, and five per cent defiers move the answer to 1.2667.

instrument · Exclusion
The same error, caught or invisible, by how it is arranged. The overidentification test's rejection rate against the error the violation actually puts into the estimate, so the two rows are the same estimate being equally wrong. With the whole violation on one instrument the test keeps its size at 5.0% under the null and reaches 86.4% by an error of 0.800. With both instruments violating in the same ratio as their first stages the two Wald ratios are identical, the test has nothing to compare, and it rejects at 5.8% at that same error — its own size. Over 1000 draws of 300 rows at each setting, at a nominal 5.0%. The test is a comparison between instruments and it was never a check on either.

Two instruments that disagree

The overidentification test keeps its size at 5.0% and reaches 86.4% power against a violation carried by one instrument. Against the same error carried by both in proportion to their first stages it rejects on 4.6% of draws — its own size — while the estimate is wrong by 0.3000, which is 94.2% of the confounding the instruments were brought in to remove.

instrument · Exclusion
Three intervals as one strength is spread thinner, at a concentration of 8. Coverage of three nominal 95.0% intervals on the same 1000 draws of 200 rows at each count, when a total concentration parameter of 8 is spread over 1 to 32 instruments. Two-stage least squares covers 97.2%, 96.4%, 94.0%, 86.7%, 73.2%, 51.5%. Building each row's fitted treatment from a first stage that never saw that row covers 97.1%, 97.2%, 98.3%, 97.8%, 97.9%, 98.7%. Limited-information maximum likelihood with its conventional standard error covers 97.2%, 96.7%, 95.7%, 90.9%, 85.2%, 79.0%. At one instrument the likelihood estimator is two-stage least squares exactly, which is why the first readings of those two agree to the last draw.

Leaving each row out of its own first stage

Spread a fixed first-stage strength over thirty-two instruments and two-stage least squares covers 51.5%. Build each row's fitted treatment from a first stage that never saw that row and the same draws cover 98.7% — through an interval 5.99 times as wide, around an estimate that misses by more than the whole effect on 34.7% of draws. At eight times the strength the same repair covers 95.3% and costs a width factor of 1.66.

instrument · Exclusion
Three intervals as one strength is spread thinner, at a concentration of 8. Coverage of four nominal 95.0% intervals on the same 1000 draws of 200 rows at each count, when a total concentration parameter of 8 is spread over 1 to 32 instruments. Two-stage least squares covers 97.2%, 96.4%, 94.0%, 86.7%, 73.2%, 51.5%. Building each row's fitted treatment from a first stage that never saw that row covers 97.1%, 97.2%, 98.3%, 97.8%, 97.9%, 98.7%. Limited-information maximum likelihood with its conventional standard error covers 97.2%, 96.7%, 95.7%, 90.9%, 85.2%, 79.0%. The same estimate with Bekker's many-instrument standard error covers 97.2%, 97.2%, 97.2%, 95.0%, 94.3%, 93.8%. At one instrument the likelihood estimator is two-stage least squares exactly, which is why the first readings of those two agree to the last draw.

A standard error that knows about the instruments

Limited-information maximum likelihood came out least biased when a concentration parameter of 8 was spread over thirty-two instruments, and its conventional interval covered 79.0%. Bekker's many-instrument standard error covers 93.8% on the same draws, at 63% of the jackknife's width — and it gets there with a median standard error of 0.561 against a true spread of 0.797, because it is large on the draws that need it. At eight times the strength it covers 94.9% at 91% of the jackknife's width, and nothing measured here beats it.

instrument · Exclusion

Named alongside it

The objects these essays reach for when they reach for this one.

First stageMonte CarloTwo-stage least squaresWald ratioAsymptotic biasClosed formConcentration parameterWeak instrumentCausal effectConsistencyEndogeneityExclusion restriction

All concepts