Instrumental-variable — where it appears
Named by 7 essays across 2 fields — each of them below, with the objects they name alongside it.
The assumption nothing tests
An instrument buys a causal effect with an assumption no sample can check, and the price is set by the same quantity that made the method work. The first stage it needs is 2.7778 times the violation it is assumed not to have, so a direct effect of 0.05 demands a first stage of 0.1389 and least squares wins below it.
Weak, and back where it started
A consistent instrumental estimate at two hundred rows and a concentration parameter of 0.32 is biased by 0.3220 ± 0.0142 against a least-squares inconsistency of 0.3594 — 89.6% of the way back to the problem it was hired to solve. Just identified, it has no mean at all, and that is measured as a rate rather than assumed.
Adjusting for everything
"Control for every covariate that was measured" leaves a larger bias than controlling for nothing on 65.5% of four thousand randomly drawn structures and a smaller one on 33.8%. Its squared error is 4.110 times that of using no covariate at all, and half of it sits in its worst tenth of structures.
Whose effect it is
With a perfectly valid instrument and no violation of anything, the estimate converges on 1.1000 where the population average effect is 0.5000. The gap is exactly θ(1 − p_c), the always-takers and never-takers cancel out of both halves of the ratio, and five per cent defiers move the answer to 1.2667.
Two instruments that disagree
The overidentification test keeps its size at 5.0% and reaches 86.4% power against a violation carried by one instrument. Against the same error carried by both in proportion to their first stages it rejects on 4.6% of draws — its own size — while the estimate is wrong by 0.3000, which is 94.2% of the confounding the instruments were brought in to remove.
Leaving each row out of its own first stage
Spread a fixed first-stage strength over thirty-two instruments and two-stage least squares covers 51.5%. Build each row's fitted treatment from a first stage that never saw that row and the same draws cover 98.7% — through an interval 5.99 times as wide, around an estimate that misses by more than the whole effect on 34.7% of draws. At eight times the strength the same repair covers 95.3% and costs a width factor of 1.66.
A standard error that knows about the instruments
Limited-information maximum likelihood came out least biased when a concentration parameter of 8 was spread over thirty-two instruments, and its conventional interval covered 79.0%. Bekker's many-instrument standard error covers 93.8% on the same draws, at 63% of the jackknife's width — and it gets there with a median standard error of 0.561 against a true spread of 0.797, because it is large on the draws that need it. At eight times the strength it covers 94.9% at 91% of the jackknife's width, and nothing measured here beats it.
Named alongside it
The objects these essays reach for when they reach for this one.
First stageMonte CarloTwo-stage least squaresWald ratioAsymptotic biasClosed formConcentration parameterWeak instrumentCausal effectConsistencyEndogeneityExclusion restriction