Concept

Concentration parameter — where it appears

The population signal in a first stage, n Σπ² divided by the residual variance of the treatment. The expected first-stage F statistic is one plus this quantity per instrument, and the standard approximation for two-stage bias is the least-squares inconsistency divided by that F.

Named by 4 essays across one field — each of them below, with the objects they name alongside it.

A weak instrument gives back the problem it was hired for. The counted mean bias of two-stage least squares at 4 instruments and 200 rows, over 2000 draws a setting, against the standard approximation and against the least-squares inconsistency the instrument was brought in to remove. At π = 0.02 the counted bias is 0.3220 ± 0.0142 where least squares is out by 0.3594 — 89.6% of the way back. At π = 0.3 it is 0.0118 against 0.2647. The approximation, the inconsistency over the population first-stage F, tracks the count at the weak end and sits above it in the middle: 0.968, 0.971, 0.918, 0.810, 0.740, 0.722, 0.846 as the ratio of counted to approximated bias.

Weak, and back where it started

A consistent instrumental estimate at two hundred rows and a concentration parameter of 0.32 is biased by 0.3220 ± 0.0142 against a least-squares inconsistency of 0.3594 — 89.6% of the way back to the problem it was hired to solve. Just identified, it has no mean at all, and that is measured as a rate rather than assumed.

instrument · Exclusion
The interval that over-covers when the instrument fails. Counted coverage of two nominal 95.0% intervals for the same causal effect, read off the same 2000 draws of 200 rows at each first stage. The exact Anderson–Rubin set covers 95.3% at every setting — flat, because the statistic it inverts is built from y − tβ, which contains no π at all, and is therefore the same number on the same draw whatever the instrument is worth. The conventional interval covers 99.1% at π = 0.02 and 95.6% at π = 0.6: it goes wrong at the weak end by covering too MUCH, at a median width of 7.320, because its standard error is computed from residuals taken at an estimate that has itself gone wrong. A weak instrument does not make this interval lie about its coverage; it makes it useless while telling the truth.

What the first stage does not know

A single weak instrument does not make the conventional interval undercover — it makes it cover 99.1% at a width of 7.320. Where the promise actually breaks is many instruments — coverage falls from 97.2% to 51.5% while the median width falls from 1.454 to 0.583.

instrument · Exclusion
Three intervals as one strength is spread thinner, at a concentration of 8. Coverage of three nominal 95.0% intervals on the same 1000 draws of 200 rows at each count, when a total concentration parameter of 8 is spread over 1 to 32 instruments. Two-stage least squares covers 97.2%, 96.4%, 94.0%, 86.7%, 73.2%, 51.5%. Building each row's fitted treatment from a first stage that never saw that row covers 97.1%, 97.2%, 98.3%, 97.8%, 97.9%, 98.7%. Limited-information maximum likelihood with its conventional standard error covers 97.2%, 96.7%, 95.7%, 90.9%, 85.2%, 79.0%. At one instrument the likelihood estimator is two-stage least squares exactly, which is why the first readings of those two agree to the last draw.

Leaving each row out of its own first stage

Spread a fixed first-stage strength over thirty-two instruments and two-stage least squares covers 51.5%. Build each row's fitted treatment from a first stage that never saw that row and the same draws cover 98.7% — through an interval 5.99 times as wide, around an estimate that misses by more than the whole effect on 34.7% of draws. At eight times the strength the same repair covers 95.3% and costs a width factor of 1.66.

instrument · Exclusion
Three intervals as one strength is spread thinner, at a concentration of 8. Coverage of four nominal 95.0% intervals on the same 1000 draws of 200 rows at each count, when a total concentration parameter of 8 is spread over 1 to 32 instruments. Two-stage least squares covers 97.2%, 96.4%, 94.0%, 86.7%, 73.2%, 51.5%. Building each row's fitted treatment from a first stage that never saw that row covers 97.1%, 97.2%, 98.3%, 97.8%, 97.9%, 98.7%. Limited-information maximum likelihood with its conventional standard error covers 97.2%, 96.7%, 95.7%, 90.9%, 85.2%, 79.0%. The same estimate with Bekker's many-instrument standard error covers 97.2%, 97.2%, 97.2%, 95.0%, 94.3%, 93.8%. At one instrument the likelihood estimator is two-stage least squares exactly, which is why the first readings of those two agree to the last draw.

A standard error that knows about the instruments

Limited-information maximum likelihood came out least biased when a concentration parameter of 8 was spread over thirty-two instruments, and its conventional interval covered 79.0%. Bekker's many-instrument standard error covers 93.8% on the same draws, at 63% of the jackknife's width — and it gets there with a median standard error of 0.561 against a true spread of 0.797, because it is large on the draws that need it. At eight times the strength it covers 94.9% at 91% of the jackknife's width, and nothing measured here beats it.

instrument · Exclusion

Named alongside it

The objects these essays reach for when they reach for this one.

First stageTwo-stage least squaresWeak instrumentInstrumental-variableInterval widthMonte CarloClosed formHeavy tailJackknife instrumental-variableLimited-information maximum likelihoodAnderson rubinApproximation error

All concepts