Field

A charge that is not a straight line

The measured charge for a tapered covariance band falls from 95% of its summed weights at two lags to 75% at thirty, so every rule that levies it as a straight line through the origin is too dear at one end and too cheap at the other. The deferral asked for a curve; the answer is that the curvature is in the denominator. Counted in the pairs the band actually uses — a lag of k is an average over n − k products — the same readings are flat from four lags up, at a spread of 0.029 against 0.081, on a correction with no fitted parameter. It repairs the one window the earlier field measured and leaves the other three wanting a curve.
The curvature is in the denominator. The optimism a Bartlett band of each width actually costs, divided by that width, on two ways of measuring the width, over 2000 draws at 120 rows. Measured in the weights the band spends — Σ w(k), which is what the earlier field levies its charges on — the reading falls from 0.9528 at two lags to 0.7486 at thirty, so a charge proportional to the summed weights is too dear at one end and too cheap at the other. Measured in the pairs the band uses — Σ w(k)(1 − k/n), because a lag of k is an average over n − k products — the same readings are flat from 4 lags up, at 0.0084 of χ² per width against 0.2359. The correction has no fitted parameter in it: it is a function of the window, the width and the sample size.

The width a band is measured in

A tapered covariance band spends 84% of its own weights at two lags and 74% at thirty. Every charge in the collection is a straight line through the origin in those weights, so it is too dear at one end and too cheap at the other.

The curvature is in the denominator. The optimism a Bartlett band of each width actually costs, divided by that width, on two ways of measuring the width, over 2000 draws at 120 rows. Measured in the weights the band spends — Σ w(k), which is what the earlier field levies its charges on — the reading falls from 0.9528 at two lags to 0.7486 at thirty, so a charge proportional to the summed weights is too dear at one end and too cheap at the other. Measured in the pairs the band uses — Σ w(k)(1 − k/n), because a lag of k is an average over n − k products — the same readings are flat from 4 lags up, at 0.0084 of χ² per width against 0.2359. The correction has no fitted parameter in it: it is a function of the window, the width and the sample size.

A lag the sample has less of

A sample autocovariance at lag k is an average over n − k products, not n. Count a band's width in the pairs it actually has and the curvature in its charge goes away, on a correction with nothing fitted in it.

A line in the right width beats two curves. How far each candidate charge sits from the measured optimism across the plateau, in units of each width's own standard error, over 2000 draws. The straight line through the origin in the band's summed weights — which is what the earlier field levies — misses by 0.2382 per width. The same straight line in the pairs the band actually uses, Σ w(k)(1 − k/n), misses by 0.0095. A fitted power law misses by 0.0293 and a fitted decaying rate by 0.0172, both on one fitted constant more. The deferral this field answers asked for a curve; the answer is a line, in a variable with nothing fitted in it.

A line that beats two curves

A deferral asked for a curve. Fitted against the same measurements, a straight line in a variable nobody had to fit describes the plateau better than either curve does with a constant more — and for three windows out of four it does not.

The scale moves the width; the curve does not. The band width each charge picks, averaged over 150 draws of 120 rows. The two conventions — a unit a lag and half a log n a lag — pick 6.08 and 3.65 lags. The four charges derived from the measured optimism pick 15.05, 15.60, 15.47 and 15.44, against a best width on the draw of 14.13. So the scale a charge is levied on moves the width by a factor of 4.27 and the shape of the charge moves it by 3.6%. None of the six is an estimate of the draw's own best width: the correlations are -0.006, -0.003, 0.017, -0.001, 0.016, -0.004.

What a better charge buys

Four charges derived from the same measurements pick band widths within six per cent of each other and deliver errors within two per cent of the gap any of them leaves. The scale a charge is levied on decides the width; the shape of the charge decides nothing.

Largest where least is needed. What the pairs correction supplies against what each window's measured profile needs, across this field's plateau, over 2000 draws at 120 rows. Both are stated as the multiplicative rise the charge per unit of width has to take between four lags and thirty. What the correction supplies is arithmetic — (1 − μ(4)/n)/(1 − μ(30)/n), where μ is the mean lag of the weight the band adds — and it runs 1.0795, 1.0580, 1.0456, 1.0539 for the four windows. What the measurement needs runs 1.1076, 1.2928, 1.2296, 1.6550. The two orderings are opposite: the plain Bartlett window has the longest mean lag, so it gets the biggest correction, and the flattest profile, so it needs the smallest. They coincide to 0.9746 of each other, and nowhere else does the correction account for more than 85.0% of the fall.

What the correction assumes

A correction with nothing fitted in it repairs one window of four. The reason is that its size is set by where a window puts its weight and the curvature it must repair is set by something else — and for one window at one sample size the two happen to agree.

Reading the draw changes what is charged, not what is tracked. The correlation between the band width each rule picks and the best band width on the same draw, over 400 draws. The three fixed charges read -0.069, -0.066, 0.012. The three that read the sample read -0.012, -0.019, -0.041. None of the six is distinguishable from nothing. The statistic the first plug-in reads does vary — the draw's own summed squared autocorrelation runs from 2.06 to 10.19 with a mean of 4.36 — so the failure is not that the charge stopped moving. It is that what it moves with carries no information about which width this draw wanted.

A charge that reads the draw

Three charges built to read the sample track the best band width on their own draw at −0.012, −0.019 and −0.041, deliver more error than the fixed rule they are calibrated to, and pick a width half again as variable. The statistic moves; the answer does not.

All essays